Influence of Heterogeneous Foundation on the Safety of Inverted Cone Bottom Oil Storage Tanks under Earthquakes
Author(s): |
Zuhao Dai
Hong Qiao Xvdong Hao Yijuan Wang Hanwen Lei Zhiqiang Cui |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Buildings, 28 June 2023, n. 7, v. 13 |
Page(s): | 1720 |
DOI: | 10.3390/buildings13071720 |
Abstract: |
In order to study the mechanical properties of inverted cone bottom oil storage tanks under earthquakes when the foundation is uneven, finite element modeling calculation for a 20,000 m³ storage tank is carried out based on ANSYS Workbench. Wind load, hydraulic pressure load, and seismic load are all equalized as distributed loads with varying spatial positions. Considering various combinations of different heterogeneous foundations and seismic loads, and by adjusting the preset foundation bed coefficient, the final foundation bed coefficient and the maximum foundation settlement value when the equivalent stress of the tank floor reaches yield strength under different conditions are calculated. The results show that under the condition of heterogeneous foundation stiffness considering seismic action, when the coefficient of local foundation bed is higher than that of natural silty clay, the requirement for safe use of the inverted cone bottom storage tank can be met. Among the seven simulated heterogeneous foundation forms, the form with high foundation stiffness on the windward side has a great influence on the safety of storage tanks. |
Copyright: | © 2023 by the authors; licensee MDPI, Basel, Switzerland. |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
6.21 MB
- About this
data sheet - Reference-ID
10737610 - Published on:
03/09/2023 - Last updated on:
14/09/2023