Identificación de las dos bocas de incendio equipadas más desfavorables en instalaciones fijas de protección contra incendios en la edificación = Identification of two more unfavorable Standpipe Hose System in fixed facilities of protection against fires

Author(s):

Medium: journal article
Language(s): Spanish
Published in: Anales de Edificación, , n. 3, v. 3
Page(s): 1
DOI: 10.20868/ade.2017.3673
Abstract:

El Reglamento de Protección Contra Incendios, y en relación con las instalaciones fijas de extinción basadas en Bocas de Incendio Equipadas (BB.II.EE), prescribe que dichas instalaciones deben proporcionar al menos durante una hora unas presiones y caudales mínimos, en las hipótesis de funcionamiento simultáneo de las dos Bocas hidráulicamente más desfavorables, por lo que las condiciones establecidas de presión, caudal y reserva de agua deberán estar adecuadamente garantizadas. Ahora bien, la normativa no especifica a que BB.II.EE se deben aplicar los requerimientos anteriores; tan sólo se dice que a las dos bocas hidráulicamente más desfavorables. Es habitual, dado que resulta aparentemente razonable, que al diseñar una instalación contra incendios se consideren como bocas más desfavorables las dos bocas más lejanas, y más elevadas, de existir, siendo el objetivo de este trabajo mostrar que no siempre se cumple la regla de que las dos Bocas de Incendio más desfavorables sean las más alejadas del grupo de presión, pretendiendo también establecer criterios para seleccionar dichas BB.II.EE. Este análisis es importante porque es posible que si una instalación no cumple a priori las exigencias de la normativa, y las BB.II.EE no proporcionan los caudales suficientes, ello podría tener como consecuencia la no extinción del fuego desarrollado.AbstractThe Protection regulation Against Fires, and in relation with the fixed facilities of extinction based on Standpipe Hose System (BB.II.EE), prescribes that the above mentioned facilities must provide at least during an hour a few pressures and minimal flows, in the hypotheses of simultaneous functioning of both Standpipe Hose System hydraulically more unfavorable, for what the conditions established of pressure, flow and water reservation will have to be guaranteed adequately. Now then, the regulation does not specify to that BB.II.EE must to him apply the previous requirements; only it is said that to both Standpipe Hose System hydraulically more unfavorable. It is habitual, provided that it turns out seemingly reasonable, that on having designed an installation against fires are considered to be more unfavorable Standpipe Hose System more distant, and higher, of existing, being the aim of this work to show that not always there is fulfilled the rule of which both most unfavorable Standpipe Hose System are more far from the group of pressure, trying to establish also criteria to select the above mentioned BB.II.EE. This analysis is important because it is possible that if an installation does not fulfill a priori the requirements of the regulation, and the BB.II.EE do not provide the sufficient flows, it might take as a consequence not extinction of the developed fire.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.20868/ade.2017.3673.
  • About this
    data sheet
  • Reference-ID
    10322028
  • Published on:
    12/07/2019
  • Last updated on:
    08/05/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine