Hygrothermal simulation of cathedral ceiling roofs with ventilated roofing tiles
Author(s): |
Philipp Kölsch
|
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | International Journal of Building Pathology and Adaptation, August 2019, n. 4, v. 37 |
Page(s): | 473-487 |
DOI: | 10.1108/ijbpa-06-2018-0049 |
Abstract: |
PurposeThe surface temperature of the sub-roof beneath the ventilation layer and the tiles is one of the most important factors for the hygrothermal performance of pitched roofs. The air layer between tiles and sub-roof and the air exchange with the outdoor air influence the heat transfer and therefore affect the moisture level inside the roof construction. The paper aims to discuss these issues. Design/methodology/approachThis paper provides the results of a research project performed at Fraunhofer-Institute for Building Physics, based on field test results. The investigations analyze the thermal behavior of different vented and ventilated roof constructions. FindingsIt was found that for a detailed model with roof cladding and ventilated air layer normally too many parameters are unknown. For that reason a simplified approach was set up, especially to consider the radiation exchange between the tiles and the underlay as well as the effects of the ventilation. Originality/valueNow, effective surface transfer parameters can substitute both cladding and air layer in the simulation, while the approach still provides a high accordance with the measured values. The paper provides characteristic values for different roofing situations to simulate ventilated roofs by means of hygrothermal simulation in a simplified way. |
- About this
data sheet - Reference-ID
10396754 - Published on:
05/12/2019 - Last updated on:
05/12/2019