Experimental Study on Seismic Performance of Transversely Ribbed Corrugated Steel Plate–Steel Pipe Concrete Shear Wall

Author(s):

Medium: journal article
Language(s): English
Published in: Buildings, , n. 9, v. 14
Page(s): 2708
DOI: 10.3390/buildings14092708
Abstract:

To enhance the seismic resilience of building structures and refine the stability and longevity of buildings, it is essential to implement strategies that not only reinforce their structural integrity but also ensure their enduring functionality. The seismic performance test of corrugated steel plate–concrete–filled steel tube shear walls with transverse ribs was studied. Three specimens of shear walls featuring transversely ribbed corrugated steel plates filled with concrete were fabricated, namely, a C–shaped shear wall with four square steel tube concrete columns (specimen C40), a C–shaped shear wall with vertical loading beams (specimen C40X), and a C–shaped shear wall with two steel tube concrete columns (specimen C40LX). Each specimen was equipped with transverse–rib corrugated steel plates with the same parameters. The seismic performances of the specimens were tested by applying loads to different specimens through the displacement–controlled loading system. The tests show that the hysteretic curves of test piece C40 and test piece C40X are not full compared with that of test piece C40LX; the cracking load, yield load, peak load, and ultimate load of both are significantly lower than those of test piece C40LX; and the energy consumption levels of test piece C40 and test piece C40X are relatively weak. The test piece C40LX obviously has a high ductility coefficient, and the stiffness decrease under load is relatively small. During the loading process, the strain change law of the vertical reinforcement in the bottom section of the wall also maintains a reasonable state. It can be seen that the C–shaped transverse–rib corrugated steel plate–concrete–filled steel tube shear wall with two concrete–filled steel tube columns has a higher seismic performance.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10795218
  • Published on:
    01/09/2024
  • Last updated on:
    01/09/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine