0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Experimental investigations into the application of direct tension indicators with preloaded structural bolting assemblies (HV system) to EN 1090-2

Author(s):

Medium: journal article
Language(s): English
Published in: Steel Construction, , n. 3, v. 5
Page(s): 168-174
DOI: 10.1002/stco.201210021
Abstract:

EN 1090-2 provides several tightening methods for the preloading of bolting assemblies. One of the prescribed procedures is the use of direct tension indicators, so-called DTIs, with lubrication according to k-class K0. According to the definition of k-class K0, the lubrication should not have an influence on achieving the required preloading force Fp,C. For this reason, the main focus of the investigations presented here was how the lubrication influences the behaviour of preloaded HV bolting assemblies with and without DTIs. The experimental investigations were carried out on the institute's own tightening torque testing machine.

Keywords:
direct tension indicator EN 1090-2 preloaded high-strength structural bolting assemblies HV system lubrication of bolting assemblies tightening methods
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/stco.201210021.