Experimental Investigation on the Cyclic In-Plane Behavior of GFRP-Reinforced Concrete Shear Walls

Author(s):
ORCID


Medium: journal article
Language(s): English
Published in: Buildings, , n. 11, v. 12
Page(s): 1948
DOI: 10.3390/buildings12111948
Abstract:

The current study presents an experimental investigation performed on slender reinforced concrete shear walls, representing a common lateral-load resisting system of mid-rise buildings. The walls were reinforced with steel and glass fiber-reinforced polymer (GFRP) bars and tested up to failure under reversed quasi-static cyclic loading to investigate the capability of GFRP bars in reinforcing RC shear walls under seismic loads. Moreover, the effect of the GFRP reinforcement ratio on the structural response, deformation performance, and failure mode resulting in RC walls, compared with its behavior when reinforced with steel bars, is also investigated. Six full-scale shear walls with an aspect ratio of 3.25 were constructed. The reference wall was entirely reinforced with steel bars. Two specimens were reinforced by hybrid scheme of GFRP–steel bars. The remaining three shear walls were entirely reinforced with GFRP bars. The overall performance of each wall was characterized by investigating the lateral load capacity, hysteretic response, cracks propagation, ductility, and the behavior of energy dissipation. The experimental results showed that GFRP-reinforced concrete walls had an elastic behavior characterized by a stable hysteretic response with recoverable deformation of more than 80% of the ultimate load. However, sudden and brittle failure was attained for the wall with a high GFRP reinforcement ratio. GFRP decreases the displacement ductility of the shear walls by an average of 32.9%, depending on the reinforcement ratio, compared to that reinforced by steel bars. Moreover, lower energy dissipation through inelastic deformation was obtained for the walls reinforced with GFRP bars. Nonetheless, when GFRP bars are combined with steel bars, acceptable levels of dissipated energy are attained compared to the steel-reinforced wall.

Copyright: © 2022 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10699754
  • Published on:
    10/12/2022
  • Last updated on:
    15/02/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine