Evaluation der Bauteiltemperierung für den Herzogskasten Abensberg

Author(s):

Medium: journal article
Language(s): German
Published in: Bauphysik, , n. 2, v. 37
Page(s): 96-99
DOI: 10.1002/bapi.201510010
Abstract:

Evaluation of component heating for the Herzogskasten monument at Abensberg.

Component tempering as a means to mitigate moisture-driven damage, i.e. direct heating of structural elements in contact with the soil or otherwise moisture-loaded building components, could also improve the building energy efficiency and even comply with the German Energy Saving Ordinance (EnEV), without any further insulation measures. This hypothesis, in addition to an evaluation of the drying-off effect, is taken under closer inspection using the Herzogskasten monument at Abensberg by comparing calculated energy demands, based on DIN V 18599 calculations, with real energy consumption data.

Keywords:
DIN V 18599 restoration monument German building energy conservation ordinance energy-efficient rehabilitation component tempering building refurbishment Energy efficiency of buildings historical monument
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/bapi.201510010.