Evaluating BIPV Façades in a Building Envelope in Hot Districts for Enhancing Sustainable Ranking: A Saudi Arabian Perspective

Author(s):
ORCID
Medium: journal article
Language(s): English
Published in: Buildings, , n. 5, v. 13
Page(s): 1110
DOI: 10.3390/buildings13051110
Abstract:

Enhancing contractual construction project documents with sustainability and green building requirements reflects growing concerns for the majority of organizations in hot zone districts. The aim is to provide a healthy, best functional performance, safe environment with occupant comfort, and an efficient building performance as an environmental-friendly building. This research study develops a holistic evaluation system for the façade composite of contractual documents. The aim of the current study was to enhance building energy performance under the sustainability rating system focusing on adapting active envelope energy applications. The research used technical evaluation with energy simulation based PVsyst V7.1.0 software and contractual status evaluation for an ongoing unique case study project in Saudi Arabia. Feasibility analysis was carried out for a sustainable active envelope using the adopted specifications of the Building Integrated Photovoltaics (BIPV) façade item instead of the contractual passive item in the Giftedness and Creativity Center project. The project was registered in the sustainability rating system called Leadership in Energy and Environmental Design (LEED). The results showed that using BIPV facades as an active renewable energy source enhances building energy performance over the project life cycle. Additionally, it generates 68% of energy demand as a nearly-zero energy project. Several other advantages include lower cost than tender cost without any contractual conflicts, energy savings per year, project upgrade to the platinum certificate, added value to the public investment, CO2 emission reduction, and barrels of oil saved.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10728322
  • Published on:
    30/05/2023
  • Last updated on:
    01/06/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine