Evaluación de problemas patológicos asociados a carbonatación y sulfatos en una torre de concreto con más de 50 años de servicio
Author(s): |
Erick Edgar Maldonado Bandala
Demetrio Nieves Mendoza Juan Luis Vela Jimenez Pedro Castro Borges |
---|---|
Medium: | journal article |
Language(s): | Spanish |
Published in: | Revista ALCONPAT, 1 February 2018, n. 1, v. 8 |
Page(s): | 94 |
DOI: | 10.21041/ra.v8i1.284 |
Abstract: |
In preparation for rehabilitation of a 50+ year-old reinforced concrete tower in the southern portion of the state of Veracruz, Mexico, inspections and assays were done to quantify corrosion in the structure. Visual damage survey was done using an aerial drone, and physical, chemical, mechanical and electrochemical assays run to characterize concrete condition and corrosion damage. Carbonation is the predominant corrosion mechanism in the structure. Sulfate emission in the surrounding industrial installations is reflected in low compression resistance, cracks and spalling. Considering the concrete condition and corrosion results, a five-step repair and rehabilitation process is proposed to extend structure service life. |