Ermüdung sehr großer HV-Schraubengarnituren
Author(s): |
Peter Schaumann
Rasmus Eichstädt |
---|---|
Medium: | journal article |
Language(s): | German |
Published in: | Stahlbau, September 2016, n. 9, v. 85 |
Page(s): | 604-611 |
DOI: | 10.1002/stab.201610410 |
Abstract: |
Fatigue of very large high-strength bolting assemblies.The fatigue characteristics of high-strength bolting assemblies (System HV) with very large diameters, as they are commonly applied in support structures for wind turbines, are not conclusively investigated yet. S-N curves, which are applicable for fatigue verification, are mostly validated on smaller bolt diameters. In this paper new experimental results of thus far unique fatigue tests on very large M64 HV-bolt sets are presented and results are integrated into the existing state of knowledge concerning fatigue of large-size bolts. Based on the enhanced test basis normative regulations are verified for very large bolt diameters and relevant influence parameter as mean stress, size effect and impact of hot-dip galvanizing are discussed. |
Keywords: |
fatigue size effect wind turbine fatigue ver flanged connection ring-flange connection hot-dip galvanized normativ regulation mean stress
|
Available from: | Refer to publisher |
- About this
data sheet - Reference-ID
10073772 - Published on:
02/10/2016 - Last updated on:
02/10/2016