0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Elasto-Plastic Bearing Capacity of Four Types of Single-Layer Reticulated Shell Structures Under Fire Hazards

Author(s):


Medium: journal article
Language(s): English
Published in: International Journal of Structural Stability and Dynamics, , n. 3, v. 15
Page(s): 1450051
DOI: 10.1142/s0219455414500515
Abstract:

Single-layer reticulated shells are widely used in spatial structures. One critical factor that has to be considered in the design of reticulated shells is the significant adverse impact of high temperature caused by fire on the structures. In order to study the variation of elasto-plastic bearing capacity under high temperature by fire, four types of single-layer reticulated shells (i.e. K6, Geodesic, Schwedler and Lamella) are investigated under two typical fire conditions (i.e. global nonuniform temperature distribution and local high temperature) by the geometrically and materially nonlinear analysis and statistical methods. Practical design formulae for calculating the elasto-plastic bearing capacity of reticulated shell structures under different fire conditions and ambient temperatures are proposed based on the numerical simulation results.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1142/s0219455414500515.
  • About this
    data sheet
  • Reference-ID
    10352651
  • Published on:
    14/08/2019
  • Last updated on:
    14/08/2019
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine