Effects of cross-sectional shape on the reliability of RC columns

Author(s):

Medium: journal article
Language(s): English
Published in: Structural Concrete, , n. 4, v. 12
Page(s): 262-269
DOI: 10.1002/suco.201100019
Abstract:

This paper studies the effects of cross-sectional shape and rebar configuration on the reliability indices of concrete columns. Three sections with rectangular, square and circular shapes are selected. Using the Monte Carlo simulation technique, the statistical parameters for reinforced column resistance are calculated along several load eccentricities using the most recent statistical data available in the literature. The statistical parameters show that the magnitude and the variation of bias factors and the coefficients of variation are not similar for the sections selected. The coefficients of variation of the square and circular sections are greater than that of the rectangular section. The results of reliability analysis indicate the importance of sectional shape, especially at low load eccentricities. In some cases, the effect of cross-sectional shape or reinforcement configuration is found to be more important than the effect of the compressive strength of the concrete. It is recommended to include the shape factor and the reinforcement configuration in the code calibration process for the capacity reduction factors.

Keywords:
limit states safety reliability index load and resistance factors RC columns load combinations
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/suco.201100019.
  • About this
    data sheet
  • Reference-ID
    10066319
  • Published on:
    08/05/2012
  • Last updated on:
    13/08/2014
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine