The Effectiveness of Pre-Cast Wall-Piles in Reducing Ground Vibration
Author(s): |
K. Hayakawa
Y. Kani N. Matsubara R. D. Woods |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Building Acoustics, September 1998, n. 3, v. 5 |
Page(s): | 185-199 |
DOI: | 10.1177/1351010x9800500303 |
Abstract: |
This paper presents the results of a study of the effectiveness of pre-cast wall-piles for controlling ground vibrations. Field measurements have been performed for five cases of different types of pre-cast wall-piles. A method for estimation of vibration reduction by pre-cast wall-piles has been developed, based on wave penetration theory. Vibration levels as registered on the off-side of the PC wall-piles barrier were 5 to 7 dB lower than that recorded at the site with no such barrier. Theoretical results, using the wave penetration theory showed good agreement with the field tests. |
- About this
data sheet - Reference-ID
10479479 - Published on:
16/11/2020 - Last updated on:
16/11/2020