0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Effect of Chases with Renovation Techniques on the Load Carrying Capacity of Masonry Walls

Author(s):

Medium: journal article
Language(s): English
Published in: Infrastructures, , n. 11, v. 6
Page(s): 160
DOI: 10.3390/infrastructures6110160
Abstract:

Infrastructure through the masonry walls (for example, wiring and piping works) are usually installed using chases in different directions. Introducing these chases in a newly built wall will affect its overall load carrying capacity. However, there has thus far been very limited research into the effects of chases on the response and load carrying capacity of walls. This study has been undertaken to evaluate the structural behaviour of new masonry walls having chases in both horizontal and vertical directions and subjected to compression load throughout an extensive experimental programme. In addition, two renovation techniques have been proposed to infill the chases created in small scale walls (wallettes). The first technique involved the use of plastic wire mesh and cement mortar, while the second incorporated using galvanized steel channel together with the plastic wire mesh and cement mortar. Furthermore, a reference case of wallette without chases has been considered to enable reasonable comparisons to check the effect of the chases and the efficiency of the proposed renovation techniques. The outcomes of this study were used to modify the design equations proposed in the relevant codes of practice. The obtained results showed a notable reduction in the load carrying capacity of the masonry wall due to the introduction of the chases with a reduction percentage of 29% compared to the masonry wall without chase. The percentage decrease depends on the depth of the chase and the inclination angle of the load flow. The walls with horizontal chases exhibited more reduction in the load carrying capacity compared to those with vertical chases. The adopted renovation techniques using galvanized steel channel and/or plastic wire mesh with cement mortar recovered 55% and 93% of the lost load carrying capacity due to the presence of the chase and the failure was due to the de-bonded phenomena of the infill materials. Suitable factors of safety have been proposed to be incorporated in the compressive strength and modulus of elasticity formulas of the masonry walls of the BS EN codes.

Copyright: © 2021 the Authors. Licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10722967
  • Published on:
    22/04/2023
  • Last updated on:
    10/05/2023
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine