0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Double-Curvature Test of Reinforced Concrete Columns Using Shaking Table: A New Test Setup

Author(s):




Medium: journal article
Language(s): English
Published in: Civil Engineering Journal, , n. 9, v. 5
Page(s): 1863-1876
DOI: 10.28991/cej-2019-03091378
Abstract:

This paper proposes a new test setup to study the double-curvature behavior of reinforced concrete (RC) columns using shaking table. In this setup, the seismic action is simulated by the horizontal movement of a long-heavy rigid mass sitting on the top of only one test specimen. The double-curvature mechanism of specimen is affected by the movement of the concrete mass on a test rig consisting four steel hollow-section columns fully anchored to the shaking table. Application of axial load on the specimen is made possible through a pre-stressing equipment connecting to its top and bottom bases. The current setup offers two improvements over the previous ones. First, it makes available greater ranges of test data for conducting bigger sizes of the specimens. Second, it allows to directly measure the variation of axial force in the test specimens while the test implementation can be fast and easy with a high safety margin even until the complete collapse of the test units. The current test setup has been successfully applied on two ½ scaled V-shaped columns. It has been shown that the column specimen with a low axial load level of 0.05f’cAg, where f’c is the concrete strength and Ag is the cross-sectional area of the specimen, can well survive at a ground peak acceleration up to 5.5 (m/s2) with a drift ratio of approximately 2.91%. Meanwhile, the column subjected to moderate axial load level of 0.15f’cAg can survive at a higher ground peak acceleration of 8.0 (m/s2) with a drift ratio of 3.75%. Furthermore, it is experimentally evidenced that the V-shaped cross-section does not deform in-plane under seismic action. The angle between two planes corresponding to the column web and flange are up to 0.03 (rad). This finding is significant since it contradicts the plane strain assumption available in the current design practice.

Copyright: © 2019 Nguyen Ngoc Linh, Nguyen Van Hung, Nguyen Xuan Huy, Le Minh Cuong, Pham Xuan Dat
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10375079
  • Published on:
    12/09/2019
  • Last updated on:
    02/06/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine