0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Condition assessment and renovation of an aged precast reinforced concrete multi-storey building

Author(s):

Medium: journal article
Language(s): English
Published in: IOP Conference Series: Earth and Environmental Science, , n. 1, v. 1026
Page(s): 012016
DOI: 10.1088/1755-1315/1026/1/012016
Abstract:

This paper assesses the condition of a 45 years old precast reinforced concrete multistorey building and proposes innovative repair techniques for extending its service life. The residential building investigated consists of six floors, and each floor consists of 4 apartments with a total floor area of 900 m². Initially, visual inspection was conducted to identify the extent of deterioration in all parts of the building, followed by field non-destructive and destructive tests to determine the root causes of the damage. Moreover, analytical tools such as ETABS and SAFE design softwares were used by applying the same loading assumptions and material properties given by the designer, to check the compliance of the building with the safety requirements specified in ACI 318-14/SBC 304-18 building codes. The field and laboratory checks confirmed the occurrence of considerable degree of deterioration in some elements of the building due to reinforcement corrosion, alkali silica reaction (ASR), salt–scaling and leaching. The analytical checks revealed excessive deflections, due to a design error. Several advanced repair techniques including carbon fiber reinforced polymer sheets (CFRP), and steel jackets were implemented to restore the structural load carrying capacity of the columns and beams that suffered extensive deterioration. The excessive deflections were reduced below the code limit by supporting the deflected slabs using wide flanged I-section steel beams. Moreover, the Repair strategy proposed included, removal of the deteriorated concrete, coating the exposed steel bars with a protective anti-corrosive coating, and cathodic protection of the steel bars followed by injecting high strength cementitious grout.

License:

This creative work has been published under the Creative Commons Attribution 3.0 Unported (CC-BY 3.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10780684
  • Published on:
    12/05/2024
  • Last updated on:
    12/05/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine