Abstract:

A sparsely instrumented 55-story building in Osaka, Japan, had recorded unprecedented, severe, and long-duration, long-period resonating responses during the 11 March 2011 M9.0 Tohoku earthquake that occurred at 767 km distance. Thereafter, studies of the records resulted in the implementation of a significant retrofit design, comprising dampers and buckling restrained braces (BRBs). The responses of the retrofitted building were also recorded during the 24 April 2016 M7.3 Kumamoto earthquake that occurred at 478 km. The earthquake and on-demand acquired ambient response data are analyzed in this study to assess the impact of this rare, retrofitted and instrumented tall building subjected to long period strong shaking from events originating at far distances. As expected, the fundamental frequency and critical damping ratio of the building increased, albeit small, after the retrofit as compared to before the retrofit. Increase of damping percentage is a positive finding and indicates that even larger percentages may be attained under shaking stronger than the 2016 event. The records indicate that the building still experiences significant resonance, torsion, as well as a beating effect.

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1193/122216eqs249m.
  • About this
    data sheet
  • Reference-ID
    10672502
  • Published on:
    18/06/2022
  • Last updated on:
    18/06/2022
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine