0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Auswirkungen der Vorspannung auf das Tragverhalten von SL-Verbindungen

Author(s):
Medium: journal article
Language(s): German
Published in: Stahlbau, , n. 7, v. 79
Page(s): 515-520
DOI: 10.1002/stab.201001285
Abstract:

Influence of the preload on the resistance of bearing-type connections.

The design resistance of bolts under tension and shear is given in DIN 18800-1 (810) by a quadratic interaction. The question is, whether the tension due to a preload has to be taken into account. The workgroup steel construction of the Technische Universität Darmstadt, Germany, has run tests to assess the influence of the preload in bearing-type connections. In this paper the tests are presented and recommendations to take the preload into account are given.

Keywords:
structural safety design resistance high-strength bolt shearing bearing preloaded bolt prestressed bolt prestressing force
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/stab.201001285.