Ausstattung von Klassenräumen mit Einrichtungen zum Temperieren, Lüften und Belichten

Author(s):


Medium: journal article
Language(s): German
Published in: Bauphysik, , n. 3, v. 31
Page(s): 157-162
DOI: 10.1002/bapi.200910021
Abstract:

Equipment of classrooms with systems for maintaining temperature, for ventilation and for illumination

Most German classrooms are not equipped with mechanical ventilation systems. Natural ventilation controlled by the occupants opening the windows is the main way to provide fresh air. Measurements in real classrooms showed that the ventilation especially in cold season is insufficient. Hydrid ventilation systems with automatically controlled windows might reduce the prevalence of high carbon dioxide concentration inside the classrooms. The position of the air supply opening in the façade is the most sensible design task. There is still a big potential for optimization. In the frame of the project "Energy saving, thermal comfort and good indoor air quality in schools using hybrid ventilation" supported by the German Federal Ministry for Economic Affairs and Technology the properties of classrooms in the county Miesbach/Germany regarding thermal comfort, ventilation and illumination were collected.
In sum data of 106 classrooms in 22 schools were collected. The density of persons is normal to low. Approximately 80% of the rooms offer at least 2 or more square meter per pupil. 88% of the investigated classrooms are built with medium or high thermal mass. The glazed facade area is between 30 and 60% for most of the classrooms. 50% of the classrooms do not have any sun shading device. The summer overheating protection by passive means is insufficient. Two thirds of the classrooms offer a good to acceptable daylight condition. The classrooms are ventilated by opening the windows. There are different opening types of the windows and several combinations of the types in the façades. Tilt and turn windows and the horizontally pivot-hung type are the most prevalent types.

Keywords:
school building summer overheating protection ventilation indoor climate interior climate summer thermal insulation
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/bapi.200910021.
  • About this
    data sheet
  • Reference-ID
    10058336
  • Published on:
    16/11/2010
  • Last updated on:
    13/08/2014
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine