Application of Modified-Partial Capacity Design Method on 6- and 15-story Square Buildings with Variation in number of Elastic Columns
Author(s): |
Pamuda Pudjisuryadi
Benjamin Lumantarna Fransisca Wijaya C. Aphrodita A. Jesica Y. Karyanto M. K. Theodora |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Civil Engineering Dimension / Dimensi Teknik Sipil, 22 April 2022, n. 1, v. 24 |
Page(s): | 46-53 |
DOI: | 10.9744/ced.24.1.46-53 |
Abstract: |
Modified-Partial Capacity Design (M-PCD) is proposed as one alternative of structural design methods. In M-PCD, the partial side sway mechanism where beams and some columns may develop plastic hinges. This method uses two structural models during the design process. The models are used to simulate undamaged and damaged structures when subjected to design earthquake (R=8.0) and larger target earthquake (R=1.6) respectively. In this study, 6- and 15-story square buildings with 30% and 50% elastic column are designed using M-PCD. Performances of the buildings are investigated by using non-linear time history analysis. Results show that the buildings’ performances are still unsatisfactory, especially for the 15-story buildings. However, it should be noted that the levels of earthquakes used for the analysis were larger than that used for the design. A more accurate prediction of the required strength should be developed further to improve M-PCD. |
Copyright: | © All right reserved 2022. Civil Engineering Dimension |
License: | This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met. |
1.14 MB
- About this
data sheet - Reference-ID
10664223 - Published on:
09/05/2022 - Last updated on:
01/06/2022