0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Application and testing of plastic fibre reinforced dry-mix shotcrete / Einsatz und Prüfung von kunststofffaserbewehrtem Trockenspritzbeton

Author(s):



Medium: journal article
Language(s): English, German
Published in: Geomechanics and Tunnelling, , n. 1, v. 4
Page(s): 63-69
DOI: 10.1002/geot.201100001
Abstract:

The Conrad Observatory in the state of Lower Austria is a geophysical research and development facility of the Central Institute for Meteorology and Geodynamics (ZAMG). The isolation of the tunnel system fulfils the optimal requirements for high-precision measurements. The client specified shotcrete class EV700 for the plastic fibre-reinforced shotcrete, i.e. the test bodies have to show an energy absorption capacity of at least 700 J in the slab test. The quality verification for the suitability of a fibre-reinforced shotcrete is performed according to the ÖVBB guideline "Sprayed Concrete" with a slab test as defined in the Austrian standard ÖNORM EN 14488-5, which can determine the energy absorption capacity and assign the shotcrete to an energy absorption class. The test rig used at the Chair of Subsurface Engineering is described, together with test results from different plastic fibre shotcretes from various testing institutes.

Keywords:
energy absorption shotcrete slab test energy absorption capacity plastic fibres dry mix shotcrete ÖNORM EN 14488-5
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/geot.201100001.
  • About this
    data sheet
  • Reference-ID
    10064800
  • Published on:
    05/04/2011
  • Last updated on:
    13/08/2014
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine