Anwendung der Zonenmethode für brandbeanspruchte Stahlbetonstützen

Author(s):

Medium: journal article
Language(s): German
Published in: Beton- und Stahlbetonbau, , n. 12, v. 104
Page(s): 813-822
DOI: 10.1002/best.200900008
Abstract:

Use of a Simplified Method (Zone Method) for Concrete Columns Exposed to Fire

Eurocode 2 provides a fire resistance check for concrete columns called zone method (simplified calculation method). Some European countries already allow this check. Germany will probably reject this method for concrete columns, as the results from the zone method partly differ from the accepted advanced method. In the authors' opinion, one reason for the differences might be lack of documentation or lack of detailed rules for the zone method. Using the zone method as a nonlinear method - even though it is based on the assumptions of plastic theory - already lead to decisive misinterpretations or misunderstandings. Hence, this article shows briefly the original assumptions and derivation of basic formulas for the zone method according to Hertz.
The use of the zone method for compression members is demonstrated with documented calibrating examples. It is displayed, how to calculate the ultimate load and the load-bearingbehaviour with adequate accuracy.

Keywords:
modeling fire safety EC dimensioninig compression members
Available from: Refer to publisher
Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1002/best.200900008.
  • About this
    data sheet
  • Reference-ID
    10062273
  • Published on:
    19/11/2010
  • Last updated on:
    13/08/2014
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine