Analysis of Cylindrical Masonry Shell in St. Jacob`s Church in Dolenja Trebuša, Slovenia—Case Study

Author(s):


Medium: journal article
Language(s): English
Published in: Buildings, , n. 5, v. 9
Page(s): 127
DOI: 10.3390/buildings9050127
Abstract:

This paper focuses on identifying key reasons for the damage of the cylindrical masonry shell structure in St. Jacob`s church in Dolenja Trebuša, Slovenia. Typical damage patterns which can be formed in shell structures and may affect the load bearing capacity are outlined. Several stress states (membrane, bending and also combined stress state) that can occur in the shell structure are described. Load cases such as the vertical displacement of the support structure, temperature loading, weight of maintenance team and also seismic loading are taken into account in order to identify the actual cause for the registered crack pattern in the shell structure. Analysis of the shell structure is performed using the SAP2000 structural software. Based on the obtained results, which highlighted key reasons for registered damage, the monitoring of cracks is recommended in the first phase, and, in continuation, the most appropriate repair and strengthening measures are proposed.

Copyright: © 2019 by the authors; licensee MDPI, Basel, Switzerland.
License:

This creative work has been published under the Creative Commons Attribution 4.0 International (CC-BY 4.0) license which allows copying, and redistribution as well as adaptation of the original work provided appropriate credit is given to the original author and the conditions of the license are met.

  • About this
    data sheet
  • Reference-ID
    10325142
  • Published on:
    22/07/2019
  • Last updated on:
    02/06/2021
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine