Acoustical Design and Noise Control in Metro Stations: Case Studies of the Ankara Metro System
Author(s): |
Zühre Sü
Mehmet Çalişkan |
---|---|
Medium: | journal article |
Language(s): | English |
Published in: | Building Acoustics, September 2007, n. 3, v. 14 |
Page(s): | 203-221 |
DOI: | 10.1260/135101007781998910 |
Abstract: |
The aim of this research is to demonstrate the importance of initial strategies in acoustical design of underground metro stations. The paper searches for practical design solutions by evaluating different materials for providing optimum acoustical conditions in such spaces. Acoustical designs of three metro stations on a new expansion line in Ankara including Sogutozu, Bilkent and ODTU metro stations are presented through computer simulation. Predictions of room acoustical parameters are presented for both platform and ticket office floors in terms of parameters like reverberation time (RT), speech transmission index (STI) and A-weighted sound level (SPL) distribution within spaces. Simulated reverberation times are evaluated in view of legislative requirements. The study confirms the importance of using sound absorbing materials on the ceiling and sidewalls together. The nonwoven material, used behind perforated metal suspended ceilings, has proved effective in reverberation control. |
- About this
data sheet - Reference-ID
10479271 - Published on:
16/11/2020 - Last updated on:
16/11/2020