Wind Induced Response Analysis and Vibration Mitigation Design for Steel Tall Buildings Equipped with Viscous Dampers

 Wind Induced Response Analysis and Vibration Mitigation Design for Steel Tall Buildings Equipped with Viscous Dampers
Author(s): , , ,
Presented at IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, published in , pp. 249-257
DOI: 10.2749/nanjing.2022.0249
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.18 MB

The wind induced response of the steel tall building is obvious. Controlling the wind induced response of steel tall building can effectively improve the comfort, stiffness and strength performance...
Read more

Bibliographic Details

Author(s): (Department of Structural Engineering, Tongji University, Shanghai, China Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
(Department of Structural Engineering, Tongji University, Shanghai, China Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
(Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
(Tongji Architectural Design (Group) Co., Ltd., Shanghai, China)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Published in:
Page(s): 249-257 Total no. of pages: 9
Page(s): 249-257
Total no. of pages: 9
DOI: 10.2749/nanjing.2022.0249
Abstract:

The wind induced response of the steel tall building is obvious. Controlling the wind induced response of steel tall building can effectively improve the comfort, stiffness and strength performance of the structure. A large number of studies have shown that equipping damping device is a more effective wind-induced vibration control measure than increasing the structure stiffness. Viscous damps can achieve multi-load and multi-performance structure vibration reduction and have a very broad engineering application prospect. In this paper, the wind induced response of steel tall building and the viscous damper system are studied to ascertain the optimal arrangement and quantity of viscous damps and a 150m steel residential tower is taken as an engineering case, which shows that the integrated viscous damps can effectively improve the structure performance of steel tall building under wind load and reduce the steel consumption of the structure.

Keywords:
high-rise buildings viscous damper steel tall building wind induced response analysis