0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Study on Tensional Countermeasures for

 Study on Tensional Countermeasures for
Author(s): , ,
Presented at IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017, published in , pp. 770-776
DOI: 10.2749/vancouver.2017.0770
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.25 MB

For easily calculating the cable tension force of cable-stayed bridges with parallel strand stayed cables, the cable-stayed bridges were simplified as a equivalent model consisting of serially or p...
Read more

Bibliographic Details

Author(s): (Tongji Architectual Design (Group) Co,.Ltd, Shanghai, China)
(Tongji University, Shanghai, China)
(Tongji University, Shanghai, China)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017
Published in:
Page(s): 770-776 Total no. of pages: 7
Page(s): 770-776
Total no. of pages: 7
Year: 2017
DOI: 10.2749/vancouver.2017.0770
Abstract:

For easily calculating the cable tension force of cable-stayed bridges with parallel strand stayed cables, the cable-stayed bridges were simplified as a equivalent model consisting of serially or parallelly interconnected springs which were employed to instead of bridge elements such as towers, cables, and beams. . For this equivalent model, simplified formulas for calculating the tension force were deduced, and a corresponded calculation process was presented. The comparison of these proposed formulas with other calculation methods showed that the proposed formulas are reliable. A parametric study centralized on the proposed formulas was carried out in order to understand the characteristics of them. The study results suggested that stiffness ratio and tension coefficient had significant effects on the discrepancy of calculation, and the tension coefficient was more sensitive to the discrete discrepancy and total discrepancy of the final cable’s force; equivalent tension has many advantages in practical construction operations, so a reasonable tensional countermeasure should be chosen according to the structural stiffness and the right tension coefficient should be estimated according to the tension range of jack at the same time.

Keywords:
the equivalent model of series-parallel connected springs simplified algorithm variance analysis ratio of stiffness coefficient of tension tensional countermeasures