Author(s): , ,
Presented at IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018, published in , pp. 726-731
DOI: 10.2749/kualalumpur.2018.0726
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.28 MB

Two test series with various UHPC strengthening interventions were conducted in this study to investigate the behaviour of composite reinforced concrete (RC) slabs strengthened with UHPC. The first...
Read more

Bibliographic Details

Author(s): (Heriot Watt University Malaysia (HWUM), Putrajaya, Malaysia)
(Hokkaido University, Japan)
(Hokkaido University, Japan)
Medium: conference paper
Language(s): English
Conference: IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018
Published in:
Page(s): 726-731 Total no. of pages: 6
Page(s): 726-731
Total no. of pages: 6
DOI: 10.2749/kualalumpur.2018.0726
Abstract:

Two test series with various UHPC strengthening interventions were conducted in this study to investigate the behaviour of composite reinforced concrete (RC) slabs strengthened with UHPC. The first, RE series is a retrofit interventions, tested UHPC as patch material for repairing deteriorated concrete structures. As for the second, OV series is a UHPC overlay interventions, was used to strengthen soffit of RC slab members. The results showed that, in RE series, UHPC safeguard against diagonal cracking compare to conventional RC slab. The UHPC exhibited excellent energy absorption with extensive deflection hardening and ductility during the post cracking range. In OV series, all slabs showed formation of diagonal shear cracks and sign of debonding modes. The UHPC overlay delayed the development of shear cracking. The ultimate load carrying capacity and tendency of flexural failure increase with the overlay thickness.

Keywords:
slabs strengthening retrofit UHPC