0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Rehabilitation of an industrial building in three different solutions

 Rehabilitation of an industrial building in three different solutions
Author(s): ,
Presented at IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010, published in , pp. 702-703
DOI: 10.2749/222137810796063337
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.04 MB

This paper presents a case study of single-storey steel buildings imported from another country. The frame was analyzed to meet the specific requirements of the Romanian design codes and results sh...
Read more

Bibliographic Details

Author(s):

Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010
Published in:
Page(s): 702-703 Total no. of pages: 7
Page(s): 702-703
Total no. of pages: 7
Year: 2010
DOI: 10.2749/222137810796063337
Abstract:

This paper presents a case study of single-storey steel buildings imported from another country. The frame was analyzed to meet the specific requirements of the Romanian design codes and results show that the structure requires retrofitting. Three cases are suggested, each of the three cases are analyzed and subjected to some concluding remarks.

Keywords:
steel single-storey building retrofitting statically systems