Recent failures of external prestressing grouted tendons: the paramount role of the HDPE duct

 Recent failures of external prestressing grouted tendons: the paramount role of the HDPE duct
Author(s): , , , ,
Presented at IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021, published in , pp. 775-782
DOI: 10.2749/christchurch.2021.0775
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.2 MB

The article describes recent cases of tendon ruptures by corrosion and investigations carried out on some bridges. Several causes related to HDPE ducts have been identified as damages during handli...
Read more

Bibliographic Details

Author(s): (Université Gustave Eiffel, IFSTTAR, Champs sur Marne & Nantes, France)
(Université Gustave Eiffel, IFSTTAR, Champs sur Marne & Nantes, France)
(Université Gustave Eiffel, IFSTTAR, Champs sur Marne & Nantes, France)
(Cerema, Lille & Bron & Bordeaux, France)
(Cerema, Lille & Bron & Bordeaux, France)
(Cerema, Lille & Bron & Bordeaux, France)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Resilient technologies for sustainable infrastructure, Christchurch, New Zealand, 3-5 February 2021
Published in:
Page(s): 775-782 Total no. of pages: 8
Page(s): 775-782
Total no. of pages: 8
DOI: 10.2749/christchurch.2021.0775
Abstract:

The article describes recent cases of tendon ruptures by corrosion and investigations carried out on some bridges. Several causes related to HDPE ducts have been identified as damages during handling, degradation during threading and tensioning of strands, defective connection of the duct to the anchor body, damage during construction or operation, low quality of HDPE material, etc.

A warning note on existing structures with external prestressing has been updated by Cerema in November 2018. It describes the diagnosis methodology based on detailed inspection, destructive and non-destructive techniques. New non-destructive investigation techniques such as guided- wave ultrasonic technique and magnetic leakage field test using permanent magnets and induction coils are presented. Innovative methods of local repair of the ducts are presented. Different protective devices are analyzed with regards of safety of workers in the case of a sudden failure of tendon.

Keywords:
testing corrosion grout repair external prestressing safety HDPE rupture diagnosis investigations