0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Practical Design of Continuous Two Main-span Suspension Bridge in Korea

 Practical Design of Continuous Two Main-span Suspension Bridge in Korea
Author(s): , , ,
Presented at IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010, published in , pp. 284-285
DOI: 10.2749/222137810796024501
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.04 MB

Recent years, multi-span cable supported bridges can be considered as viable alternatives instead of bridges with very long span in certain bridge environments. However, only a few multi-span suspe...
Read more

Bibliographic Details

Author(s):



Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Large Structures and Infrastructures for Environmentally Constrained and Urbanised Areas, Venice, Italy, 22-24 September 2010
Published in:
Page(s): 284-285 Total no. of pages: 6
Page(s): 284-285
Total no. of pages: 6
Year: 2010
DOI: 10.2749/222137810796024501
Abstract:

Recent years, multi-span cable supported bridges can be considered as viable alternatives instead of bridges with very long span in certain bridge environments. However, only a few multi-span suspension bridges have yet been constructed. This paper presents the practical design of continuous two main-spans suspension bridge in Korea. The total length of the bridge is 1,750m with three pylons and two main-spans. The length of each main span is 650m and the side span is 225m in length. The pentagonal shape of stiffening girder is applied to secure the safety of aerodynamic stability. There are special design precautions to be considered in the design of multi- span continuous suspension bridge, such as the deflection of bridge spans and the cable slip at the middle pylon’s cable saddle. To solve those problems, parametric studies were performed and the optimized section of pylon was determined. In addition, the state-of-the-art technologies such as a high strength cable with 1960MPa in strength are adopted. In this paper, the economic efficiency of designed bridge is also briefly discussed by comparing with the mechanical behavior of other types of bridge with similar environmental conditions.

Keywords:
Multi-span suspension bridge two main-span high-strength cable concrete saddle