Author(s): , ORCID, , ,
Presented at IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016, published in , pp. 1803-1811
DOI: 10.2749/stockholm.2016.1808
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.19 MB

Several measuring techniques based on digital image correlation (DIC) are nowadays used in many fields. DIC measurements can facilitate documentation of crack patterns on specimens subject to loadi...
Read more

Bibliographic Details

Author(s): (Luleå University of Technology, Luleå, Sweden)
ORCID (Luleå University of Technology, Luleå, Sweden)
(Luleå University of Technology, Luleå, Sweden)
(Luleå University of Technology, Luleå, Sweden)
(Luleå University of Technology, Luleå, Sweden)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Published in:
Page(s): 1803-1811 Total no. of pages: 9
Page(s): 1803-1811
Total no. of pages: 9
Year: 2016
DOI: 10.2749/stockholm.2016.1808
Abstract:

Several measuring techniques based on digital image correlation (DIC) are nowadays used in many fields. DIC measurements can facilitate documentation of crack patterns on specimens subject to loading, valuable information, which would otherwise be hard to obtain, especially in the case of reinforced concrete elements. This can not only give a better insight into the failure mechanism of the element, but also evaluate cracking as measure of serviceability.

This article discusses existing serviceability limits and failure modes of reinforced concrete walls in buildings in light of results obtained using DIC on two half-scale reinforced concrete walls with openings tested to failure. Results suggest that cracks induced by a load level equivalent to 70% of ultimate load bearing capacity, do not exceed limits indicated in relevant guidelines.

The failure mode of two way walls with openings was found to be similar to that of two way slabs also with openings, however differences were identified in the development of the failure mechanism. Finally, two strengthening strategies of reinforced concrete walls are discussed.

Keywords:
reinforced concrete openings serviceability walls digital image correlation DIC crack mapping