Bridges are composed by many structural members, such as girders, deck slabs, cross-frames, etc., which interact each other to resist various load combinations. In the traditional bridge design met...
Read more

Bibliographic Details

Author(s): (Osaka City University, Osaka, Japan)
(Osaka City University, Osaka, Japan)
(Oriental Consultants Co., Ltd., Tokyo, Japan)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Published in:
Page(s): 1747-1754 Total no. of pages: 8
Page(s): 1747-1754
Total no. of pages: 8
DOI: 10.2749/prague.2022.1747
Abstract:

Bridges are composed by many structural members, such as girders, deck slabs, cross-frames, etc., which interact each other to resist various load combinations. In the traditional bridge design method, the structural member is usually analyzed as an independent part/member without considering the structural system behavior.

In present study, a whole-scale FE analysis has been conducted for a steel I-girder bridge system with corrosion damages, considering the behavior of the bridge as a system by removing its structural members one by one. It is found from the analytical results that the deck slab and cross- frames are effective for load sharing when corrosion occurs at the girder end of the outer girder subjected to vertical load. As the damage increases, reduction of the maximum load when the deck slab is removed is larger than that of the cross-frames removal. We have also confirmed that the deck slab and cross-frames work as alternative load sharing paths to each other.

Keywords:
bridge system steel I-girder bridge load sharing corrosion ratio
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

This creative work is copyrighted material and may not be used without explicit approval by the author and/or copyright owner.

Structure Types