Judgement methods of fire resistance time of hybrid reinforced concrete beams

 Judgement methods of fire resistance time of hybrid reinforced concrete beams
Author(s): ,
Presented at IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019, published in , pp. 955-960
DOI: 10.2749/guimaraes.2019.0955
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.79 MB

Hybrid reinforced concrete beams have been designed by replacing the steel bars in areas with weak durability with fiber-reinforced plastic bars. This paper suggests the judgement methods of fire r...
Read more

Bibliographic Details

Author(s): (Ph.D. Candidate, Dept. of Structural Engineering, Tongji Univ., Shanghai 200092, People’s Republic of China.)
(Professor, Dept. of Structural Engineering, Tongji Univ., Shanghai 200092, People’s Republic of China.)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019
Published in:
Page(s): 955-960 Total no. of pages: 6
Page(s): 955-960
Total no. of pages: 6
DOI: 10.2749/guimaraes.2019.0955
Abstract:

Hybrid reinforced concrete beams have been designed by replacing the steel bars in areas with weak durability with fiber-reinforced plastic bars. This paper suggests the judgement methods of fire resistance time of hybrid reinforced concrete beams by considering about the judgement methods of fire resistance time of steel reinforced concrete beams and FRP reinforced concrete beams that were proposed by scholars and standards of various countries. Six hybrid reinforced concrete beams were subjected to a fire test. The deflection and the temperature of hybrid reinforced concrete beams in the fire test were recorded. These judgement methods suggested by these scholars and standards are applied in judging the fire resistance time of these six hybrid reinforced concrete beams respectively. The results are compared to suggest that almost all the main factors having a great influence on fire resistance time of hybrid reinforced concrete beams are considered by the deformation limitation method, and this method can be taken as the main determinant in the judgement methods. The heat insulation of beams and the average temperatures of the surface of beams cannot be used directly to judge the fire resistance time. The judgement methods are improved by combination of these methods so that the judgement methods can be used for the design.

Keywords:
fiber-reinforced plastic hybrid reinforced concrete beams judgement methods of fire resistance time