Fire Resistance Performance of Prefabricated Composite Floor System Infilled with Phase Change Material

 Fire Resistance Performance of Prefabricated Composite Floor System Infilled with Phase Change Material
Author(s): , , ,
Presented at IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017, published in , pp. 454-461
DOI: 10.2749/vancouver.2017.0454
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.19 MB

In South Korea, the most common floor system installed on steel frames have been deck slab system. Disadvantage of this system is increasing construction duration due to concrete curing and additio...
Read more

Bibliographic Details

Author(s): (Korea University, Seongbuk, Seoul, South Korea)
(Korea University, Seongbuk, Seoul, South Korea)
(Korea University, Seongbuk, Seoul, South Korea)
(Seoul National University of Science and Technology, Nowon, Seoul, South Korea)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017
Published in:
Page(s): 454-461 Total no. of pages: 8
Page(s): 454-461
Total no. of pages: 8
Year: 2017
DOI: 10.2749/vancouver.2017.0454
Abstract:

In South Korea, the most common floor system installed on steel frames have been deck slab system. Disadvantage of this system is increasing construction duration due to concrete curing and additional fireproofing protection works. As fireproofing protection installed by people handwork had low quality and material wastes, floor systems that had fire resistance performance and easily applied to steel frames started being developed. Prefabricated Composite Floor System was also developed to apply to steel structures without fireproofing protection and features of this system were largely influenced by Phase Change Material filled inside the system. Phase Change Material could be differently made by additives and some materials were developed to enhance the fire resistance performance of systems by changing additives. In this research, the fire resistance performance of Prefabricated Composite Floor system with infilled different Phase Change Material was evaluated and predicted by using finite element analysis program ABAQUS/CAE 6.10-1. In addition, the effect of wire meshes and the type of PCM were investigated by using temperature distributions and displacements during 2 hours fire test modelled at finite element program.

Keywords:
finite element analysis FEA fire resistance prefabricated Phase Change Material heat transfer analysis Floor System Composite System