0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Experimental Testing of Mechanical Splices for Titanium Alloy Bars

 Experimental Testing of Mechanical Splices for Titanium Alloy Bars
Author(s): ,
Presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022, published in , pp. 266-271
DOI: 10.2749/prague.2022.0266
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.14 MB

Recently application of Titanium Alloy Bars (TiABs) has been gaining popularity in retrofitting of bridges in the United States using near-surface mounted techniques. TiABs offer high strength, exc...
Read more

Bibliographic Details

Author(s): (Idaho State University, Pocatello, ID, USA)
(Idaho State University, Pocatello, ID, USA)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022
Published in:
Page(s): 266-271 Total no. of pages: 6
Page(s): 266-271
Total no. of pages: 6
DOI: 10.2749/prague.2022.0266
Abstract:

Recently application of Titanium Alloy Bars (TiABs) has been gaining popularity in retrofitting of bridges in the United States using near-surface mounted techniques. TiABs offer high strength, excellent corrosion resistance, enhanced fatigue performance, lighter weight, lower stiffness, and less residual deformation beyond the yield point. Currently, there is a lack of a splicing system for TiABs. There are various mechanical splicing systems available for conventional and high-strength steels; however, they have not been investigated for splicing of TiABs. The research investigates some of the existing splicing systems for pseudo-threaded TiABs. Mechanical splices from a producer in the United States are considered for this research. Three different types of mechanical couplers are investigated for splicing of #5 (ø16mm) and #6 (ø19mm) pseudo-threaded TiABs. TiABs larger than #6 are more expensive and harder to bend, therefore #5 and #6 TiABs are more popular and have been implemented in several bridges in the United States. Tensile testing is carried out on several #5 and #6 spliced TiABs in accordance with relevant ASTM Standards to investigate suitability of each splicing system. Observations from testing showed that only one type of splicing system was able to achieve failure of TiABs at a location away from the spliced region. The other two splicing systems had premature pullout or failure of the coupler itself. Testing results suggest that the successful coupler/splicing system was in close compliance with the requirements of AASHTO LRFD that require mechanical splices to achieve more than 125% of the yield strength of the bar. Given the lower strain hardening of TiABs (1.1) compared to conventional steel (1.5), the coupler system identified in this research is concluded to be adequate for mechanical splicing of #5 and #6 TiABs subjected to monotonic tensile stresses.

Keywords:
tensile test Innovative Materials Titanium alloy bars mechanical couplers splicing
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License:

This creative work is copyrighted material and may not be used without explicit approval by the author and/or copyright owner.