0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Experimental Study on Hybrid Masonry Structure with RC Frame under Lateral Reversed Cyclic Loading

 Experimental Study on Hybrid Masonry Structure with RC Frame under Lateral Reversed Cyclic Loading
Author(s): ,
Presented at IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018, published in , pp. 135-142
DOI: 10.2749/kualalumpur.2018.0142
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.28 MB

As a new type of structural system, hybrid masonry (HM) structure with reinforced concrete (RC) frame is constructed of reinforced block masonry wall and reinforced concrete frame. This structural ...
Read more

Bibliographic Details

Author(s): (Xi’an Jiaotong University, Xi'an, P.R. China)
(Xi’an Jiaotong University, Xi'an, P.R. China)
Medium: conference paper
Language(s): English
Conference: IABSE Conference: Engineering the Developing World, Kuala Lumpur, Malaysia, 25-27 April 2018
Published in:
Page(s): 135-142 Total no. of pages: 8
Page(s): 135-142
Total no. of pages: 8
DOI: 10.2749/kualalumpur.2018.0142
Abstract:

As a new type of structural system, hybrid masonry (HM) structure with reinforced concrete (RC) frame is constructed of reinforced block masonry wall and reinforced concrete frame. This structural system combines the advantages of reinforced concrete frame structure and reinforced concrete block masonry structure, also overcomes some limitations of them. In order to study the seismic performance of the structural system, the lateral reversed cyclic loading experiment on the HM structure with RC frame was conducted. In the experiment, two specimens that were constructed with different connecting type were designed and tested, in one of them the masonry blocks was separated from the RC frame and only connected with steel keys at the top part of the specimen, while in the other there was no spacing between the RC frame and the masonry blocks. According to the data of the experiment, the paper analyzed the failure process and patterns, hysteretic characteristic, skeleton curve, stiffness degradation and displacement ductility of the structural system, and compared the results of the two specimens. The experimental study indicated that the HM structure with RC frame showed extraordinary good seismic performance during testing, and this form of construction had fairly good displacement ductility and energy dissipation, which would provide a basis for further theoretical analysis and design method.

Keywords:
skeleton curve hybrid masonry lateral reversed cyclic loading hysteretic characteristic stiffness degradation