The seismic performance of RC elements can be significantly impaired by inadequate lap-splicing of their reinforcing bars. In this paper the main findings of an experimental investigation of this i...
Read more

Bibliographic Details

Author(s): (DB Engineering & Consulting GmbH, Doha Branch, Qatar)
(DB Engineering & Consulting GmbH, Doha Branch, Qatar)
(CRD Group - Structural Health Monitoring LTD, Athens, Greece)
Medium: conference paper
Language(s): English
Conference: IABSE Congress: Challenges in Design and Construction of an Innovative and Sustainable Built Environment, Stockholm, Sweden, 21-23 September 2016
Published in:
Page(s): 1572-1579 Total no. of pages: 8
Page(s): 1572-1579
Total no. of pages: 8
Year: 2016
DOI: 10.2749/stockholm.2016.1567
Abstract:

The seismic performance of RC elements can be significantly impaired by inadequate lap-splicing of their reinforcing bars. In this paper the main findings of an experimental investigation of this influence are presented. Two rehabilitation techniques by means of external confinement of lap- splices are also examined. Cyclic tests on twelve (12) column-like specimens were performed. Four

(4) types of specimens were tested, one (1) with no reinforcement lap-splicing and three (3) with lap-splicing of their longitudinal reinforcement inside their critical regions (plastic hinges). For each type different lap-lengths were used. All specimens had the same geometry and reinforcement detailing. The tests were fully instrumented and monitored. The experimental results of this study are presented hereafter. Conclusions regarding the shear response, the hysteretic energy dissipation and the effectiveness of the strengthening techniques used are made.

Keywords:
concrete cyclic tests FRP strengthening retrofitting monitoring Eurocodes steel jacket lap-splicing fibre-optic-sensors