The Existing Champlain Bridge – Assessment Using Refined Analyses

The Existing Champlain Bridge – Assessment Using Refined Analyses
Author(s): , , ,
Presented at IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017, published in , pp. 1521-1528
DOI: 10.2749/vancouver.2017.1521
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.22 MB

In order to evaluate the performance of the post-tensioned I-girders and diaphragms in the existing Champlain Bridge, a combination of 3D linear and 2D non-linear finite element analyses were carri...
Read more

Bibliographic Details

Author(s): (McGill University, Montreal, QC, Canada)
(McGill University, Montreal, QC, Canada)
(Polytechnique Montréal, Montréal, QC, Canada)
(IDAE s.e.n.c, Montréal, QC, Canada)
Medium: conference paper
Language(s): English
Conference: IABSE Symposium: Engineering the Future, Vancouver, Canada, 21-23 September 2017
Published in:
Page(s): 1521-1528 Total no. of pages: 8
Page(s): 1521-1528
Total no. of pages: 8
Year: 2017
DOI: 10.2749/vancouver.2017.1521
Abstract:

In order to evaluate the performance of the post-tensioned I-girders and diaphragms in the existing Champlain Bridge, a combination of 3D linear and 2D non-linear finite element analyses were carried out. After 55 years in service, many girders are experiencing deterioration. The results from the 3D analyses enabled the determination of the loads applied to individual girders and diaphragms for the non-linear analyses. The 3D analyses also enabled the determination of the redistribution of forces in the structure due to different degrees of corrosion of the tendons in the girders. The 2D non-linear finite element analyses captured the responses of the girders and diaphragms and enabled an assessment of the performance under service and factored loads. The degrees of corrosion of the tendons and the stirrups were estimated from inspection results. The effects of different strengthening measures were also assessed using this approach.

Keywords:
finite element analysis FEA corrosion strengthening evaluation post-tensioning non-linear analysis deterioration Bridge Girders