Estimation of Structural Safety for Internally Grouted Post-tensioned External Tendons

 Estimation of Structural Safety for Internally Grouted Post-tensioned External Tendons
Author(s): , ORCID, ,
Presented at IABSE Workshop: Ignorance, Uncertainty, and Human Errors in Structural Engineering, Helsinki, Finland, 15-16 February 2017, published in , pp. 86-91
DOI: 10.2749/helsinki.2017.086
Price: € 25.00 incl. VAT for PDF document  
ADD TO CART
Download preview file (PDF) 0.86 MB
In February, 2016, one of the external tendons in pre‐stressed concrete (PSC) box girder bridge in Seoul was failed due to corrosion after 17 years of service. The failure was found during the thawin...
Read more

Bibliographic Details

Author(s): (Seoul National University, Seoul, Republic of Korea)
ORCID (Seoul National University, Seoul, Republic of Korea)
(Seoul National University, Seoul, Republic of Korea)
(Seoul National University, Seoul, Republic of Korea)
Medium: conference paper
Language(s): English
Conference: IABSE Workshop: Ignorance, Uncertainty, and Human Errors in Structural Engineering, Helsinki, Finland, 15-16 February 2017
Published in:
Page(s): 86-91 Total no. of pages: 6
Page(s): 86-91
Total no. of pages: 6
DOI: 10.2749/helsinki.2017.086
Abstract: In February, 2016, one of the external tendons in pre‐stressed concrete (PSC) box girder bridge in Seoul was failed due to corrosion after 17 years of service. The failure was found during the thawing season regular inspection. Since it was the first tendon failure occurred in South Korea, in‐depth investigation was performed and found that multiple tendons were corroded at many different locations. Seoul City had been preparing for the maintenance of PSC box girder bridges, but the draft maintenance guideline considered overall condition of the bridge and little attention was paid to the condition of tendons. The bridge was evaluated as per the draft guideline and rated as ‘Medium Risk’ although one external tendon was failed. The indices for the evaluation should be properly weighted to prevent failure of tendons.
Keywords:
durability tendon corrosion maintenance assessment risk matrix