Electrochemical behaviour of high-strength corrugated steel in aerated alkaline mediums
|
Bibliographic Details
Author(s): |
Siaw Foon Lee
José Fullea García Carmen Andrade Javier Sánchez |
||||
---|---|---|---|---|---|
Medium: | conference paper | ||||
Language(s): | English | ||||
Conference: | IABSE Symposium: Engineering for Progress, Nature and People, Madrid, Spain, 3-5 September 2014 | ||||
Published in: | IABSE Symposium Madrid 2014 | ||||
|
|||||
Page(s): | 896-903 | ||||
Total no. of pages: | 8 | ||||
Year: | 2014 | ||||
DOI: | 10.2749/222137814814067040 | ||||
Abstract: |
In this study, the high-strength corrugated steel wire with a diameter of 7.6 mm was subjected to different aerated alkaline mediums (pH8.2, 12.3 and 13.4) with different concentration of Cl-. The electrochemical cell was consisted of a working electrode, an auxiliary electrode and a reference electrode, which was the steel wire, the graphite rod and the Ag/AgCl in KCl saturated, respectively. The open circuit potential measurement that lasted for 8 hours and the potentiodynamic polarization measurement from -900 mV to +500 mV were performed on the steel in each different medium and Cl- concentration. After the measurement, the steel surface was examined under the light microscope to find out the types of corrosions that occurred on the steel. Regardless of the Cl- concentration, it is found that at the medium of pH8.2 general corrosions are seen on the steel surface, at pH12.3 pitting corrosions, while at pH13.4 no corrosion is observed on the steel. |
||||
Keywords: |
pitting corrosion high-strength steel open circuit potential potentiodynamic polarization
|