- Design and thermal performance of a passive cooled building for the semiarid climate of India. In: Energy and Buildings, v. 6, n. 1 (January 1984). (1984):
- Reduction of heat flux by a flowing water layer over an insulated roof. In: Building and Environment, v. 15, n. 2 (January 1980). (1980):
- Thermal modeling for greenhouse heating by using thermal curtain and an earth–air heat exchanger. In: Building and Environment, v. 41, n. 7 (July 2006). (2006):
- Evolution of design patterns for direct evaporative coolers. In: Building and Environment, v. 30, n. 2 (April 1995). (1995):
- Optimum distribution of insulation over various components of an air-conditioned building. In: Building and Environment, v. 24, n. 2 (January 1989). (1989):
- Evaluation of complex heat transfer coefficients for passive heating concepts. In: Building and Environment, v. 22, n. 4 (January 1987). (1987):
- Thermal performance of an evaporatively cooled multi-storey building. In: Building and Environment, v. 21, n. 2 (January 1986). (1986):
- Effect of finite thermal conductivity on the thermal performance of a storage medium. In: Building and Environment, v. 21, n. 3-4 ( 1986). (1986):
- Evaluation of an earth—air tunnel system for cooling/heating of a hospital complex. In: Building and Environment, v. 20, n. 2 (January 1985). (1985):
- Thermal performance of a cool-pool system for passive cooling of a non-conditioned building. In: Building and Environment, v. 20, n. 4 (January 1985). (1985):
- A thermal model of a roof pond system with moveable insulation for heating a building. In: Building and Environment, v. 17, n. 2 (January 1982). (1982):
- The relative performance of different approaches to the passive cooling of roofs. In: Building and Environment, v. 17, n. 2 (January 1982). (1982):
- Thermal performance of a solarium with removable insulation. In: Building and Environment, v. 17, n. 1 (January 1982). (1982):
- Experimental validation of thermal model of open roof pond. In: Building and Environment, v. 16, n. 2 (January 1981). (1981):
- Periodic heat transfer and load levelling of heat flux through a PCCM thermal storage wall/roof in an air-conditioned building. In: Building and Environment, v. 16, n. 2 (January 1981). (1981):
- Optimum distribution of insulation inside and outside the roof. In: Building and Environment, v. 14, n. 1 (January 1979). (1979):
- An earth-air tunnel system for cooling buildings. In: Tunnelling and Underground Space Technology, v. 1, n. 2 (January 1986). (1986):