0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

The following bibliography contains all publications indexed in this database that are linked with this name as either author, editor or any other kind of contributor.

  1. Lin, Pei-Yang / Lin, Tzu-Kang / Hwang, Jenn-Shin (2013): A semi-active mass damping system for low- and mid-rise buildings. In: Earthquakes and Structures, v. 4, n. 1 (January 2013).

    https://doi.org/10.12989/eas.2013.4.1.063

  2. Lin, Pei-Yang / Lin, Tzu-Kang (2012): Control of seismically isolated bridges by magnetorheological dampers and a rolling pendulum system. In: Structural Control and Health Monitoring, v. 19, n. 2 (March 2012).

    https://doi.org/10.1002/stc.431

  3. Loh, Chin-Hsiung / Lin, Pei-Yang / Chung, Nan-Hau (2000): Design of dampers for structures based on optimal control theory. In: Earthquake Engineering and Structural Dynamics, v. 29, n. 9 (September 2000).

    https://doi.org/10.1002/1096-9845(200009)29:9<1307::aid-eqe972>3.0.co;2-d

  4. Chen, Pei-Ching / Tsai, Keh-Chyuan / Lin, Pei-Yang (2014): Real-time hybrid testing of a smart base isolation system. In: Earthquake Engineering and Structural Dynamics, v. 43, n. 1 (June 2014).

    https://doi.org/10.1002/eqe.2341

  5. Fan, Yu-Cheng / Loh, Chin-Hsiung / Yang, Jann N. / Lin, Pei-Yang (2009): Experimental performance evaluation of an equipment isolation using MR dampers. In: Earthquake Engineering and Structural Dynamics, v. 38, n. 3 (March 2009).

    https://doi.org/10.1002/eqe.844

  6. Loh, Chin-Hsiung / Lynch, Jerome P. / Lu, Kung-Chun / Wang, Yang / Chang, Chia-Ming / Lin, Pei-Yang / Yeh, Ting-Hei (2007): Experimental verification of a wireless sensing and control system for structural control using MR dampers. In: Earthquake Engineering and Structural Dynamics, v. 36, n. 10 (August 2007).

    https://doi.org/10.1002/eqe.682

  7. Shook, David A. / Roschke, Paul N. / Lin, Pei-Yang / Loh, Chin-Hsiung (2009): Semi-active control of a torsionally-responsive structure. In: Engineering Structures, v. 31, n. 1 (January 2009).

    https://doi.org/10.1016/j.engstruct.2008.06.016

  8. Kim, Hyun-Su / Roschke, Paul N. / Lin, Pei-Yang / Loh, Chin-Hsiung (2006): Neuro-fuzzy model of hybrid semi-active base isolation system with FPS bearings and an MR damper. In: Engineering Structures, v. 28, n. 7 (June 2006).

    https://doi.org/10.1016/j.engstruct.2005.09.029

  9. Shook, David A. / Roschke, Paul N. / Lin, Pei-Yang / Loh, Chin-Hsiung (2008): GA-optimized fuzzy logic control of a large-scale building for seismic loads. In: Engineering Structures, v. 30, n. 2 (February 2008).

    https://doi.org/10.1016/j.engstruct.2007.04.008

  10. Weng, Jian-Huang / Loh, Chin-Hsiung / Lynch, Jerome P. / Lu, Kung-Chun / Lin, Pei-Yang / Wang, Yang (2008): Output-only modal identification of a cable-stayed bridge using wireless monitoring systems. In: Engineering Structures, v. 30, n. 7 (July 2008).

    https://doi.org/10.1016/j.engstruct.2007.12.002

  11. Loh, Chin-Hsiung / Weng, Jian-Huang / Liu, Yi-Cheng / Lin, Pei-Yang / Huang, Shieh-Kung (2011): Structural damage diagnosis based on on-line recursive stochastic subspace identification. In: Smart Materials and Structures, v. 20, n. 5 (May 2011).

    https://doi.org/10.1088/0964-1726/20/5/055004

  12. Shook, David / Lin, Pei-Yang / Lin, Tzu-Kang / Roschke, Paul N. (2007): A comparative study in the semi-active control of isolated structures. In: Smart Materials and Structures, v. 16, n. 4 (August 2007).

    https://doi.org/10.1088/0964-1726/16/4/058

  13. Lu, Kung-Chun / Loh, Chin-Hsiung / Yang, J. N. / Lin, Pei-Yang (2008): Decentralized sliding mode control of a building using MR dampers. In: Smart Materials and Structures, v. 17, n. 5 (October 2008).

    https://doi.org/10.1088/0964-1726/17/5/055006

Search for a publication...

Only available with
My Structurae

Full text
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine