0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

The following bibliography contains all publications indexed in this database that are linked with this name as either author, editor or any other kind of contributor.

  1. Lee, Heon-Jae / Jung, Hyung-Jo / Moon, Seok-Jun / Lee, Sung-Kyung / Park, Eun-Churn / Min, Kyung-Won (2010): Experimental Investigation of MR Damper-based Semiactive Control Algorithms for Full-scale Five-story Steel Frame Building. In: Journal of Intelligent Material Systems and Structures, v. 21, n. 10 (1 June 2010).

    https://doi.org/10.1177/1045389x10374162

  2. Park, Eunchurn / Min, Kyung-Won / Lee, Sung-Kyung / Lee, Sang-Hyun / Lee, Heon-Jae / Moon, Seok-Jun / Jung, Hyung-Jo (2010): Real-time Hybrid Test on a Semi-actively Controlled Building Structure Equipped with Full-scale MR Dampers. In: Journal of Intelligent Material Systems and Structures, v. 21, n. 18 (December 2010).

    https://doi.org/10.1177/1045389x10390253

  3. Lee, Heon-Jae / Jung, Hyung-Jo / Cho, Sang-Won / Lee, In-Won (2008): An Experimental Study of Semiactive Modal Neuro-control Scheme Using MR Damper for Building Structure. In: Journal of Intelligent Material Systems and Structures, v. 19, n. 9 (30 July 2008).

    https://doi.org/10.1177/1045389x07083024

  4. Jung, Hyung-Jo / Jang, Ji-Eun / Choi, Kang-Min / Lee, Heon-Jae (2008): MR fluid damper-based smart damping systems for long steel stay cable under wind load. In: Smart Structures and Systems, v. 4, n. 5 (September 2008).

    https://doi.org/10.12989/sss.2008.4.5.697

  5. Jung, Hyung-Jo / Jang, Dong-Doo / Lee, Heon-Jae / Lee, In-Won / Cho, Sang-Won (2010): Feasibility Test of Adaptive Passive Control System Using MR Fluid Damper with Electromagnetic Induction Part. In: Journal of Engineering Mechanics (ASCE), v. 136, n. 2 (February 2010).

    https://doi.org/10.1061/(asce)0733-9399(2010)136:2(254)

  6. Jung, Hyung-Jo / Lee, Heon-Jae / Yoon, Woo-Hyun / Oh, Ju-Won / Lee, In-Won (2004): Semiactive Neurocontrol for Seismic Response Reduction Using Smart Damping Strategy. In: Journal of Computing in Civil Engineering, v. 18, n. 3 (July 2004).

    https://doi.org/10.1061/(asce)0887-3801(2004)18:3(277)

  7. Choi, Kang Min / Lee, Heon-Jae / Cho, Sang-Won / Lee, In Won (2007): Modified energy dissipation algorithm for seismic structures using magnetorheological damper. In: KSCE Journal of Civil Engineering, v. 11, n. 2 (March 2007).

    https://doi.org/10.1007/bf02823855

  8. Moon, Seok-Jun / Huh, Young-Chul / Jung, Hyung-Jo / Jang, Dong-Doo / Lee, Heon-Jae (2011): Sub-optimal design procedure of valve-mode magnetorheological fluid dampers for structural control. In: KSCE Journal of Civil Engineering, v. 15, n. 5 (May 2011).

    https://doi.org/10.1007/s12205-011-1178-9

  9. Choi, Kang-Min / Jung, Hyung-Jo / Lee, Heon-Jae / Cho, Sang-Won (2007): Feasibility study of an MR damper-based smart passive control system employing an electromagnetic induction device. In: Smart Materials and Structures, v. 16, n. 6 (December 2007).

    https://doi.org/10.1088/0964-1726/16/6/036

  10. Lee, Heon-Jae / Yang, Guangqiang / Jung, Hyung-Jo / Spencer, Billie F. / Lee, In-Won (2006): Semi-active neurocontrol of a base-isolated benchmark structure. In: Structural Control and Health Monitoring, v. 13, n. 2-3 (March 2006).

    https://doi.org/10.1002/stc.105

  11. Choi, Kang-Min / Jung, Hyung-Jo / Lee, Heon-Jae / Cho, Sang-Won (2008): Seismic protection of base-isolated building with nonlinear isolation system using smart passive control strategy. In: Structural Control and Health Monitoring, v. 15, n. 5 (August 2008).

    https://doi.org/10.1002/stc.274