- Impact of personal protective equipment on wearer's health indicators using multi-parameter physiological monitoring. In: Building and Environment, v. 263 (September 2024). (2024):
- Effectiveness of respiratory protective equipment on source control of exhaled pollutants. In: Journal of Building Engineering, v. 86 (June 2024). (2024):
- The use of respiratory protective equipment redefines breathing zone and increases inhalation exposure of self-exhaled pollutants. In: Building and Environment, v. 247 (January 2024). (2024):
- Ventilation strategies and children's perception of the indoor environment in Swedish primary school classrooms. In: Building and Environment, v. 240 (July 2023). (2023):
- Comparison of two methods for bioaerosol sampling and characterization in a low-biomass chamber environment. In: Building and Environment, v. 240 (July 2023). (2023):
- Ventilation strategies and indoor air quality in Swedish primary school classrooms. In: Building and Environment, v. 226 (December 2022). (2022):
- CO2 emission rates from sedentary subjects under controlled laboratory conditions. In: Building and Environment, v. 211 (March 2022). (2022):
- IEQ-Compass – A Tool for Holistic Evaluation of Potential Indoor Environmental Quality. In: Building and Environment, v. 172 (April 2020). (2020):
- Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia. In: Building and Environment, v. 122 (September 2017). (2017):
- Diurnal and seasonal variation in air exchange rates and interzonal airflows measured by active and passive tracer gas in homes. In: Building and Environment, v. 104 (August 2016). (2016):
- Indoor air quality in passive and conventional new houses in Sweden. In: Building and Environment, v. 93 (November 2015). (2015):
- Indoor air quality in the Swedish housing stock and its dependence on building characteristics. In: Building and Environment, v. 69 (November 2013). (2013):
- Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior. In: Building and Environment, v. 46, n. 11 (November 2011). (2011):
- Ventilation rates in the bedrooms of 500 Danish children. In: Building and Environment, v. 45, n. 10 (October 2010). (2010):
- Sensory pollution from bag-type fiberglass ventilation filters: Conventional filter compared with filters containing various amounts of activated carbon. In: Building and Environment, v. 44, n. 10 (October 2009). (2009):
- Is the use of particle air filtration justified? Costs and benefits of filtration with regard to health effects, building cleaning and occupant productivity. In: Building and Environment, v. 43, n. 10 (October 2008). (2008):