0
  • DE
  • EN
  • FR
  • International Database and Gallery of Structures

Advertisement

Analysis and evaluation of the effect of reflectance values on internal walls, internal roofs, and light shelf on optimal illumination levels in the diploma economics and business building of the vocational school UGM, Yogyakarta

Author(s):


Medium: journal article
Language(s): English
Published in: IOP Conference Series: Earth and Environmental Science, , n. 1, v. 927
Page(s): 012030
DOI: 10.1088/1755-1315/927/1/012030
Abstract:

The use of natural light as a source of lighting in buildings is an option in energy saving. One of the efforts that has been made is the installation of a light shelf. The light shelf installed in the UGM Vocational School Economics and Business Diploma (DEB SV) building is not fully working optimally. As many as 83% of the light shelf in lecture rooms is covered by curtains because it is considered to produce excess light (glare). This results in a greater consumption of lighting electricity. This study was conducted to analyze and evaluate the effect of the reflectance value (color) attached to the internal walls, internal roof, external light shelf, and internal light shelf on the indicator of illumination levels Useful Daylight Illuminance (UDI). Furthermore, this study aims to determine the optimum reflectance value (color) parameter. The research was conducted with a simulation method using RadianceIES in the IESVE 2021 software. The first simulation results show the value of reflectance (color) installed (base case) on the internal wall, internal roof, external light shelf, and internal light shelf in one of the lecture rooms of the DEB SV UGM building resulting in a very large value of the UDI>2000lux indicator, which is 84,9% (not according to the criteria). The results of the second simulation provide two variations of the optimum reflectance (color) parameters in the independent variable. The first variation is the internal walls, internal roof, external light shelf, and internal light shelf, each of which has a reflectance value (color) of 90,67% (beige), 100% (white), 90,67% (beige), and 100% (white). The second variation is the internal walls, internal roof, exte rnal light shelf, and internal light shelf, each of which has a reflectance value (color) of 90,67% (beige), 100% (white), 90,67% (beige), and 90,67% (beige).

Structurae cannot make the full text of this publication available at this time. The full text can be accessed through the publisher via the DOI: 10.1088/1755-1315/927/1/012030.
  • About this
    data sheet
  • Reference-ID
    10780741
  • Published on:
    12/05/2024
  • Last updated on:
    12/05/2024
 
Structurae cooperates with
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine