Wind-Resistant Measures of the Busan-Geoje Fixed Link Bridges during Construction
|
Détails bibliographiques
Auteur(s): |
Young-Min Kim
Sang-Kyoon Jeong Seok-Jun Joo |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | 18th IABSE Congress: Innovative Infrastructures – Towards Human Urbanism, Seoul, Korea, 19-21 September 2012 | ||||
Publié dans: | IABSE Congress Seoul 2012 | ||||
|
|||||
Page(s): | 660-667 | ||||
Nombre total de pages (du PDF): | 8 | ||||
DOI: | 10.2749/222137912805110970 | ||||
Abstrait: |
In general, temporary tied-down cables are used on cable stayed bridges during construction for stabilization when subjected to wind loads. However, the system requires temporary concrete blocks or pile foundation. Thus, tied-down cable systems are an expensive temporary method and have the potential of causing environment pollution problems; furthermore, the system may interrupt the route of ships or induce collisions. Tuned mass damper (TMD) system is proposed to cable stayed bridges or similar structures to supress wind-induced vibrations and ensure aerodynamic stability. TMD systems are more economical and workable in comparison with the temporary tied-down cables. TMD is shown to be the most efficient solution to bridge stabilization during construction when subjected to wind loads. |
||||
Mots-clé: |
essai en soufflerie
|