0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Ultra High-rise Building with High Seismic Performance using High Efficiency Hybrid Vibration Control System: [Tokyo Garden Terrace Kioicho] Kioi Tower

 Ultra High-rise Building with High Seismic Performance using High Efficiency Hybrid Vibration Control System: [Tokyo Garden Terrace Kioicho] Kioi Tower
Auteur(s): ,
Présenté pendant IABSE Symposium: Tomorrow’s Megastructures, Nantes, France, 19-21 September 2018, publié dans , pp. S28-1
DOI: 10.2749/nantes.2018.s28-1
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.38 MB

This paper describes that Hybrid Seismic Control System is applied in Tall Building “Kioi-tower” we had designed in Tokyo, Japan.

Outline of “Kioi-tower” is as followed, 33stories plus 2 pent...
Lire plus

Détails bibliographiques

Auteur(s): (Nikken Sekkei Ltd, 2-18-3 Iidabashi, Chiyoda-ku, Tokyo, Japan 102-8117 Japan)
(Nikken Sekkei Ltd, 2-18-3 Iidabashi, Chiyoda-ku, Tokyo, Japan 102-8117 Japan)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Tomorrow’s Megastructures, Nantes, France, 19-21 September 2018
Publié dans:
Page(s): S28-1 Nombre total de pages (du PDF): 8
Page(s): S28-1
Nombre total de pages (du PDF): 8
DOI: 10.2749/nantes.2018.s28-1
Abstrait:

This paper describes that Hybrid Seismic Control System is applied in Tall Building “Kioi-tower” we had designed in Tokyo, Japan.

Outline of “Kioi-tower” is as followed, 33stories plus 2 penthouses, 5 ground floors. 177.65m high. Total Floor Area: 227,200m², Typical Floor Height: 4.45m or 3.40m. It provides office, hotel and retail. This building has Hybrid Seismic Control System means both viscous dampers and buckling restrained braces (BRBs) are used in the mega structure.

Point of the System is below,

  1. Deformation and velocity of BRBs and viscous damping braces are amplified by the Mega structure composed with transferring girder and steel plate column.

    The efficiency of energy dissipation is enhanced and shear force is reduced to 75%.

  2. Maximum axial force is reduced to 75% compared with the absolute sum of the axial force of BRBs and viscous damper because of phase differences.

Dampers of this system absorb about 15% more energy compared with only steel damper or viscous damper.

Structural monitoring system is also installed in this building. This system helps to elongate the life span of the building, and efficiently maintain seismic control devices and earthquake resistance elements easily.

Mots-clé:
amortisseur BIM