Technical Research on OVM250 PSC System with High Fatigue Strength and Full Life Cycle Durability
|
Détails bibliographiques
Auteur(s): |
Zou Yiqing
(Liuzhou OVM Machinery Co., Ltd.)
Yan Yunyou (Liuzhou OVM Machinery Co., Ltd.) Qin Lei (Liuzhou OVM Machinery Co., Ltd.) Su Qi (Liuzhou OVM Machinery Co., Ltd.) Pang Ruijian (Liuzhou OVM Machinery Co., Ltd.) Li Huaping (Liuzhou OVM Machinery Co., Ltd.) Zhu Yongquan (Liuzhou OVM Machinery Co., Ltd.) |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022 | ||||
Publié dans: | IABSE Congress Nanjing 2022 | ||||
|
|||||
Page(s): | 1739-1747 | ||||
Nombre total de pages (du PDF): | 9 | ||||
DOI: | 10.2749/nanjing.2022.1739 | ||||
Abstrait: |
With the development of modern long-span cable-stayed bridges, due to the Parallel strand cable (PSC) being assembled on-site strand by strand, which has the advantages such as no need for large-scale equipment for cable-making, delivery, hoisting, traction, tensioning, and the corrosion protection of the cable is excellent, it is more and more favored by designers. As the load-bearing components, the stay cables are known as the life cable of the cable- stayed bridge. Its reliability and durability are the key factors that determine the safety and the service life of the cable-stayed bridge. In accordance with the requirements specified in international recommendations, in-depth research has been carried out on cable fatigue, anti- corrosion, vibration control to optimize OVM250 PSC system. All research results have been successfully applied to cable stayed bridge projects. |
||||
Copyright: | © 2022 International Association for Bridge and Structural Engineering (IABSE) | ||||
License: | Cette oeuvre ne peut être utilisée sans la permission de l'auteur ou détenteur des droits. |