Shear Strength of Post-installed Diagonal Anchor
|
Détails bibliographiques
Auteur(s): |
Mitsuyoshi Ishimura
Kazushi Sadasue Koichi Minami |
||||
---|---|---|---|---|---|
Médium: | papier de conférence | ||||
Langue(s): | anglais | ||||
Conférence: | IABSE Symposium: Engineering for Progress, Nature and People, Madrid, Spain, 3-5 September 2014 | ||||
Publié dans: | IABSE Symposium Madrid 2014 | ||||
|
|||||
Page(s): | 2595-2602 | ||||
Nombre total de pages (du PDF): | 8 | ||||
Année: | 2014 | ||||
DOI: | 10.2749/222137814814069354 | ||||
Abstrait: |
Post-installed anchor is widely spread for the seismic retrofit in existing RC and SRC buildings. Usually, anchor bars are vertically installed in a concrete surface. However, we think that post-installed anchor using diagonal anchor bars improves shear strength. In this research, we confirmed the shear strength of post-installed anchor using diagonal anchor bars through the structural test. In addition, we proposed the evaluation method of shear strength for various failure modes. |
||||
Mots-clé: |
reconception pour effets sismiques
|