Shear Strength of Post-installed Diagonal Anchor
|
Bibliografische Angaben
Autor(en): |
Mitsuyoshi Ishimura
Kazushi Sadasue Koichi Minami |
||||
---|---|---|---|---|---|
Medium: | Tagungsbeitrag | ||||
Sprache(n): | Englisch | ||||
Tagung: | IABSE Symposium: Engineering for Progress, Nature and People, Madrid, Spain, 3-5 September 2014 | ||||
Veröffentlicht in: | IABSE Symposium Madrid 2014 | ||||
|
|||||
Seite(n): | 2595-2602 | ||||
Anzahl der Seiten (im PDF): | 8 | ||||
Jahr: | 2014 | ||||
DOI: | 10.2749/222137814814069354 | ||||
Abstrakt: |
Post-installed anchor is widely spread for the seismic retrofit in existing RC and SRC buildings. Usually, anchor bars are vertically installed in a concrete surface. However, we think that post-installed anchor using diagonal anchor bars improves shear strength. In this research, we confirmed the shear strength of post-installed anchor using diagonal anchor bars through the structural test. In addition, we proposed the evaluation method of shear strength for various failure modes. |
||||
Stichwörter: |
Scherfestigkeit Erdbebennachbemessung Lagerversagen
|